Real World Testing Results 2023
Covered by this topic
General Information
Plan Report ID Number | |
Developer Name | Medical Informatics Engineering |
Product Name(s) | WebChart EHR |
Version Number(s) | 8.4 |
Certified Health IT Product List ID(s) | 15.04.04.1932.WebC.84.01.0.221117 |
Developer Real World Testing Page URL | https://docs.webchartnow.com/resources/system-specifications/ehr-certification/real-world-testing/ |
Results Submission Date | 01/29/2024, resubmitted 02/29/2024 |
Changes to the Original Plan
Summary of Change | Reason | Impact |
QRDA SVAP was not completed during 2023 | Business needs prevented development from finalizing code to meet the new standards. | There was no impact on RWT activities as testing measures did not need to be updated to the newer standard. |
Certification of additional CQMs was not completed during 2023 | Business needs prioritized development and certification of b.10 and f.5 | There was no impact on RWT activities. |
Withdrawn Products
Product Names(s) | WebChart EHR |
Version Number(s) | 7.4 |
CHPL Product Number(s) | 15.04.04.1932.WebC.74.00.0.181219 |
Date(s) Withdrawn | 12/31/2022 |
Inclusion of Data in Results Report | No data was collected from WebChart EHR v7.4 during the 2023 RWT period. |
Certification Criteria to be Tested
- Care Coordination
- § 170.315(b)(1) Transitions of care (Cures Update)
- § 170.315(b)(2) Clinical information reconciliation and incorporation (Cures Update)
- § 170.315(b)(3) Electronic prescribing (Cures Update)
- § 170.315(b)(6) Data export
- § 170.315(b)(7) Security tags - summary of care - send (Cures Update)
- § 170.315(b)(8) Security tags - summary of care - receive (Cures Update)
- § 170.315(b)(9) Care plan (Cures Update)
- Clinical Quality Measures
- § 170.315(c)(1)—record and export
- § 170.315(c)(2)—import and calculate
- § 170.315(c)(3)—report (Cures Update)
- Patient Engagement
- § 170.315(e)(1) View, download, and transmit to 3rd party (Cures Update)
- Public Health
- § 170.315(f)(1) Transmission to immunization registries
- Application Programming Interfaces
- § 170.315(g)(7) Application access— patient selection
- § 170.315(g)(8) Application access— data category request
- § 170.315(g)(9) Application access— all data request (Cures Update)
- § 170.315(g)(10) Standardized API for patient and population services
- Electronic Exchange
- § 170.315(h)(1) Direct Project
Criteria-Measure Matrix
Criteria | Requirement | Measure |
§170.315(b)(1): Transitions of Care | (b)(1)(i)(A)(Alternative) - Send Using Edge Protocol for SMTP/IXE XDR | 17 |
(b)(1)(i)(B)(Alternative) - Receive Using Edge Protocol for SMTP/IXE XDR | 17 | |
(b)(1)(i)(C)(Conditional) - XDM Processing | 17 | |
(b)(1)(ii)(A) - Receive, Parse, and Process | 7, 19 | |
(b)(1)(ii)(B) - View | 7 | |
(b)(1)(ii)(C) - Section Display | 7 | |
(b)(1)(iii) - Create | 7 | |
(b)(1)(iii)(A) - Assessment, Plan, Goals, Health Concerns | 7 | |
(b)(1)(iii)(B) - Diagnoses | 7 | |
(b)(1)(iii)(C) - Cognitive Status | 7 | |
(b)(1)(iii)(D) - Functional Status | 7 | |
(b)(1)(iii)(E) - Ambulatory Referral Summary | 7 | |
(b)(1)(iii)(F) - Inpatient Discharge Instructions | 7 | |
(b)(1)(iii)(G) - Patient Matching | 7 | |
§170.315(b)(2): Clinical information reconciliation and incorporation | (b)(2)(ii) - Correct Patient | 7 |
(b)(2)(iii)(A) - Simultaneous Display | 9 | |
(b)(2)(iii)(B) - Reconciled List | 9 | |
(b)(2)(iii)(C) - User Review | 9 | |
(b)(2)(iii)(D) - List Acceptance | 9 | |
(b)(2)(iv) - CCD Creation | 9 | |
§170.315(b)(3): Electronic prescribing | (b)(3)(ii)(A)(1) - NewRx | 3 |
(b)(3)(ii)(A)(2) - RxChangeRequest, RxChangeResponse | 3 | |
(b)(3)(ii)(A)(3) - CancelRx, CancelRxResponse | 3 | |
(b)(3)(ii)(A)(4) - RxRenewalRequest, RxRenewalResponse | 3 | |
(b)(3)(ii)(A)(5) - RxFill | 3 | |
(b)(3)(ii)(A)(6) - RxHistoryRequest, RxHistoryResponse | 3 | |
(b)(3)(ii)(A)(7) - Status | 3 | |
(b)(3)(ii)(A)(8) - Error | 3 | |
(b)(3)(ii)(A)(9) - Verify | 3 | |
(b)(3)(ii)(C)(1) - Primary/Secondary Diagnosis | 4 | |
(b)(3)(ii)(E) - Metric Units | 5 | |
(b)(3)(ii)(F) - Decimal Format | 6 | |
§170.315(b)(6): Data Export | (b)(6)(i) - Configure and export | 18 |
(b)(6)(ii) - Set Export | 18, 19 | |
(b)(6)(ii)(A) - CCDS | 18, 19 | |
(b)(6)(ii)(B) - Diagnoses | 18, 19 | |
(b)(6)(ii)(C) - Cognitive Status | 18, 19 | |
(b)(6)(ii)(D) - Functional Status | 18, 19 | |
(b)(6)(ii)(E) - Ambulatory Reason for Referral | 18, 19 | |
(b)(6)(ii)(F) - Inpatient Discharge Instructions | 18, 19 | |
(b)(6)(iii)(A) - Timeframe configuration | 18 | |
(b)(6)(iii)(B) - Export summary | 18 | |
(b)(6)(iv) - Save location | 18 | |
§170.315(b)(7): Security tags - summary of care - send | (b)(7) - CDA Generated with Privacy & Security Markings | 27 |
§170.315(b)(8): Security tags - summary of care - receive | (b)(8)(i) - Security Tags Document | 28 |
(b)(8)(ii) - Preserve Privacy Markings | 28 | |
§170.315(b)(9): Care plan | (b)(9) - Record | 24 |
(b)(9) - Change and Access | 24 | |
(b)(9) - Create | 25 | |
(b)(9) - Receive | 26 | |
§170.315(c)(1): CQMs – record and export | (c )(1)(i) - Report | 1 |
(c )(1)(ii) - Export | 1 | |
§170.315(c)(2): CQMs – import and calculate | (c )(2)(i) - Import | 2 |
(c )(2)(ii) - Calculate | 1, 2 | |
§170.315(c)(3): CQMs – report | (c )(3)(i) - Report | 1, 2 |
§170.315(e)(1): View, download, and transmit to 3rd party | (e)(1)(i) - Web Content Accessibility | 21 |
(e)(1)(i)(A) - View | 14 | |
(e)(1)(i)(A)(1) - USCDI | 23 | |
(e)(1)(i)(A)(3)(i) - Assessment and Plan of Treatment | 23 | |
(e)(1)(i)(A)(3)(ii) - Goals | 23 | |
(e)(1)(i)(A)(3)(iii) - Health Concerns | 23 | |
(e)(1)(i)(A)(4) - Provider Data | 23 | |
(e)(1)(i)(A)(6) - Laboratory Test Report | 23 | |
(e)(1)(i)(A)(7) - Diagnostic Imaging Report | 23 | |
(e)(1)(i)(B)(1)(i) - Download Human Readable | 15 | |
(e)(1)(i)(B)(1)(ii) - Download CCD | 15 | |
(e)(1)(i)(B)(2) - CCD Human Readable | 15 | |
(e)(1)(i)(C)(1)(i) - Email | 16 | |
(e)(1)(i)(C)(1)(ii) - Encrypted Transmission | 16 | |
(e)(1)(i)(D)(1) - Specific Date | 14, 15, 16 | |
(e)(1)(i)(D)(2) - Date Range | 14, 15, 16 | |
(e)(1)(ii)(A) - Activity Log | 14, 15, 16 | |
§170.315(f)(1): Transmission to immunization registries | (f)(1)(i) - Create Content | 10 |
(f)(1)(ii) - Query Records | 11 | |
§170.315(g)(7): Application access – patient selection | (g)(7)(i) - Query processing and response | 20 |
(g)(7)(ii)(A)(1) - Functional Documentation | 8 | |
(g)(7)(ii)(A)(2) - Implementation Requirements | 8 | |
(g)(7)(ii)(A)(3) - Terms of Use | 8 | |
(g)(7)(ii)(B) - Public Link | 8 | |
§170.315(g)(8): Application access – data category request | (g)(8)(i)(A) - Return CCDS data | 20 |
(g)(8)(i)(B) - Request response | 20 | |
(g)(8)(ii)(A)(1) - Documentation | 8 | |
(g)(8)(ii)(A)(2) - Implementation Requirements | 8 | |
(g)(8)(ii)(A)(3) - Terms of Use | 8 | |
(g)(8)(ii)(B) - Public URL | 8 | |
§170.315(g)(9): Application access—all data request | (g)(9)(i)(A)(1) - Demonstrate API | 20 |
(g)(9)(i)(A)(3) - Data Classes | 20 | |
(g)(9)(i)(B) - Data Return | 20 | |
(g)(9)(ii)(A)(1) - Documentation | 8 | |
(g)(9)(ii)(A)(2) - Implementation Requirements | 8 | |
(g)(9)(ii)(B) - Public URL | 8 | |
§170.315(g)(10): Standardized API for patient and population services | (g)(10)(i) - Data response: USCDI v1 + US Core STU v3.1.1 | 29, 30, 31 |
(g)(10)(ii) - Supported search operations | 29, 30, 31 | |
(g)(10)(iii) - Application registration | 29, 30, 31 | |
(g)(10)(iv) - Secure connection | 29, 30, 31 | |
(g)(10)(v)(A) - Authentication and authorization for patient and user scopes: SMART 1.0.0 | 29, 30 | |
(g)(10)(v)(B) - Authentication and authorization for system scopes | 29, 31 | |
(g)(10)(vi) - Patient authorization revocation | 29, 30 | |
(g)(10)(vii) - Token introspection | 30, 31 | |
(g)(10)(vii) - Documentation | 22 | |
§170.315(h)(1): Direct Project | (h)(1)(i) - Send | 12 |
(h)(1)(i) - Receive | 13 | |
(h)(1)(ii) - Message Disposition Notification: Processed | 12 | |
(h)(1)(ii) - Message Disposition Notification: Failed | 12 |
Care Setting(s)
WebChart EHR is a scalable, web-based system designed for ambulatory practices and clinics. The same product is distributed to all care settings with many configuration options. Each practice can use the available configuration to tailor the product to fit their workflows and use requirements. Unless noted, testing for each measure was conducted for all care settings.
Care Setting | Justification |
Primary Care | The WebChart EHR clients are divided primarily between primary care and specialty practices. Testing in a primary care setting will cover a large and important portion of our business. |
Specialty Practice | The WebChart EHR clients are divided primarily between primary care and specialty practices. Configuration selections are all that differentiate WebChart EHR implementations; however, we will test with several specialty practices to ensure configuration does not impact the functionality of certified capabilities. |
Pediatrics | Pediatric clinics are typically configured differently than adult primary care clinics. We will test in a pediatric setting in addition to primary care to again ensure that configuration does not impact the functionality of certified capabilities. |
Small/Rural/Underserved Practice | The size and location of a practice can impact their interoperability options. We will test with both small/rural and large/urban practices to ensure all practices have full interoperability functionality. |
Large Multi-practice Clinic | The size and location of a practice can impact their interoperability options. We will test with both small/rural and large/urban practices to ensure all practices have full interoperability functionality. |
Summary of Testing Methods and Key Findings
WebChart EHR is a cloud-based, fully-inclusive EHR solution. All certified functionality is delivered in all instances of the product regardless of the care setting, size of practice, or required use cases for a given practice. Each production client is maintained in a separate database; however, the implementation of the environment is identical with the exception of optional increased security protocols that a client may choose to add for enhanced data protection. Additionally, the only differences between the client-facing portion of each system are a result of configuration settings that can be selected at go-live or updated at any time during a client’s contract. Due to this philosophy of product delivery, all certified capabilities may not be actively used in all marketed care settings or may not be actively used in any current client production system. To address the Real World Testing requirements, MIE will be using a hybrid approach. Testing will primarily be conducted using de-identified real patient data from production systems as recorded in database tables and log files. For those criteria for which this live production recording is not available or minimal due to lack of client usage, client reported issues will be tracked and reported in addition to enacting automated tests of the certified functionality in a test system in a production environment. The automated tests will be run daily or weekly as appropriate in a system that is identical in substance and delivery to a client production system with the only exception being live real patient data. This blended approach will allow MIE to prove ongoing maintenance of WebChart EHR’s certified technology regardless of the level of implementation by current clients.
Throughout 2023, we generally found a reduction of errors and misuse of modules when compared to 2022. The testing of e-Prescribing functionality, CCDA creation, data export, and documentation availability were particularly successful in production environments with real patient data. Conversely, many of WebChart EHR’s certified capabilities are still heavily underutilized by clients, especially use of the FHIR API, Direct Messaging, and special use of CDAs (care plan, security tags). These APIs present challenges for real world testing since test patients and environments, despite mirroring production systems, do not truly represent the end-user interoperability experience. Due to the development priority of supporting (b)(10), improving the robustness of the testing infrastructure did not receive the development attention as planned; however, MIE remains dedicated to both improving the testing infrastructure as well as continuing to educate clients regarding these features that are available and valuable to their practice.
Measures Used in Overall Approach
The following measures outline and justify how each requirement of all criteria to which WebChart EHR is certified will be tested during the 2023 Real World Testing year. Please review the Criteria-Measure Matrix above to review which measure(s) will cover a specific requirement.
Measure 1: Clinical Quality Measures Outgoing
Description
This measure will review WebChart EHR’s ability to measure clinical quality and export the required information. Compliance will be tested both manually by developers and clients as well as automatically by reporting bodies and the Cypress CUV+ test system.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(c)(1): CQMs – record and export | (c )(1)(i) - Record |
(c )(1)(ii) - Export | |
§170.315(c)(2): CQMs – import and calculate | (c )(2)(ii) - Calculate |
§170.315(c)(3): CQMs – report | (c )(3)(i) - Report |
Justification
WebChart EHR should accommodate the full range of §170.315(c)(1), §170.315(c)(2), and §170.315(c)(3) to support providers participating in MIPS and other quality measures. Most data supporting these measures for existing clients will come from data generated internally by their standard clinical workflows of seeing patients or incorporating the CCDA of transitioning patients. Numerical compliance calculations and reporting will be monitored by MIE and the practices selected for testing. The export and report QRDA formats will be validated by reporting partners and Cypress CUV+ to ensure data collected and calculated in WebChart EHR remains interoperable.
Test Methodology
First, MIE will install an instance of Cypress 7+ on our production servers following all of our protocols for maintaining the security of PHI. Cypress CUV+ supports the validation of QRDA reports containing PHI and will be used monthly to validate a random selection of QRDAs from the care settings identified. Any errors identified by Cypress CUV+ will be tracked, reported, and addressed, then followed with testing of a larger sample of files.
Additionally, WebChart EHR has two customers that participate in quarterly attestations using both QRDA I and QRDA III reports. These customers regularly inspect their CQM compliance numbers and will alert MIE to any perceived errors. MIE will then collect and track the attestation results from the reporting bodies including any errors so as to report a success/failure rate.
Results
Calculations | QRDA I | QRDA III | |
Client Reported Issues | 0 | 0 | 0 |
Submitted Files | N/A | 4836 | 5 |
Submission Errors | N/A | 0 | 0 |
Tested Files | N/A | 4368 | 156 |
Testing Errors | N/A | 0 | 0 |
Discussion
As expected, no errors were found in formatting or coding of the certified measures.
Measure 2: Clinical Quality Measures Incoming
Description
This measure will review WebChart EHR’s ability to measure clinical quality and export the required information. Compliance will be tested both manually by developers and clients as well as automatically by reporting bodies and the Cypress CUV+ test system.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(c)(2): CQMs – import and calculate | (c )(2)(i) - Import |
(c )(2)(ii) - Calculate | |
§170.315(c)(3): CQMs – report | (c )(3)(i) - Report |
Justification
WebChart EHR should accommodate the full range of §170.315(c)(1), §170.315(c)(2), and §170.315(c)(3) to support providers participating in MIPS and other quality measures. It is rare that an active production client will import a QRDA I file for use in their CQM calculations. To maintain that WebChart EHR is capable of importing and calculating when this does occur, QRDA I files from Cypress will be imported into a test system in a production environment, CQMs will be automatically calculated, and QRDA files will be exported back to Cypress for content and calculation validation.
Test Methodology
MIE will install an instance of Cypress 7+ on our production servers following all of our protocols for maintaining the security of PHI. Automated testing will download QRDA I files from Cypress for each certified CQM, import the files to WebChart EHR, calculate the CQMs, and export the QRDA files for Cypress validation of both the content and calculations to verify that the import was successful. Any errors identified by Cypress will be tracked, reported, and addressed.
Results
QRDA I | QRDA III | |
Tested Files | 4368 | 156 |
Testing Errors | 0 | 0 |
Discussion
As expected, no errors were found in formatting or coding of the certified measures.
Measure 3: E-Prescribing Messages Sent and Received
Description
This measure will verify that all supported e-prescribing message types are in use in WebChart EHR, including inbound and outbound message types.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(3): Electronic prescribing | (b)(3)(ii)(A)(1) - NewRx |
(b)(3)(ii)(A)(2) - RxChangeRequest, RxChangeResponse | |
(b)(3)(ii)(A)(3) - CancelRx, CancelRxResponse | |
(b)(3)(ii)(A)(4) - RxRenewalRequest, RxRenewalResponse | |
(b)(3)(ii)(A)(5) - RxFill | |
(b)(3)(ii)(A)(6) - RxHistoryRequest, RxHistoryResponse | |
(b)(3)(ii)(A)(7) - Status | |
(b)(3)(ii)(A)(8) - Error | |
(b)(3)(ii)(A)(9) - Verify |
Justification
WebChart EHR should support all of the required e-prescribing messaging types outlined in §170.315(b)(3). Messages are stored locally in each client system in addition to being transmitted to/from pharmacies via the Surescripts network.
Test Methodology
MIE will report a count of messages for each supported message type:
* NewRx
* RxChangeRequest
* RxChangeResponse
* CancelRx
* CancelRxResponse
* RxRenewalRequest
* RxRenewalResponse
* RxFill
* RxHistoryRequest
* RxHistoryResponse
* Status
* Error
* Verify
The report will also include a count of outbound messages unable to be transmitted due to connectivity issues or other errors, for each message type. This report will be based on the contents of each client’s local database table of stored messages. MIE will run the report for each client under consideration and aggregate the results.
Results
Message Type | Client Message Counts | Total Count | ||||
NewRx | 42246 | 128192 | 220909 | 9648 | 32279 | 433274 |
RxChangeRequest | 4 | 2957 | 650 | 0 | 858 | 4469 |
RxChangeResponse | 0 | 2471 | 346 | 0 | 869 | 3686 |
CancelRx | 58 | 26 | 591 | 0 | 2 | 677 |
CancelRxReponse | 58 | 23 | 574 | 0 | 1 | 656 |
RxRenewalRequest | 12034 | 53759 | 13958 | 0 | 7267 | 87018 |
RxRenewalResponse | 12368 | 52186 | 13843 | 0 | 7244 | 85641 |
RxFill | 0 | 0 | 0 | 0 | 1782 | 1782 |
RxHistoryRequest | 9 | 10 | 0 | 1 | 3 | 23 |
RxHistoryResponse | 5 | 6 | 0 | 1 | 2 | 14 |
Status | 110083 | 389337 | 430122 | 17831 | 82420 | 1029793 |
Error | 550 | 2677 | 1060 | 83 | 292 | 4662 |
Verify | 43477 | 150276 | 179860 | 8261 | 32206 | 414080 |
Total error rate: 4662 / 2065775 * 100 = 0.22%
Discussion
As expected, all supported message types have a greater than zero total message count, and the total number of messages far exceeds the number of errored messages with a total error rate of 0.22%. This is an overall reduction in error rate from 0.24% in 2022 to 0.22% in 2023. Additionally, the number of NewRx messages is significantly greater than the number of RxChangeResponse, CancelRx, and RxRenewalResponse messages.
Measure 4: E-Prescribing Diagnosis Codes
Description
This measure will verify that all diagnosis elements are present in some e-prescribing messages as required by §170.315(b)(3), including inbound and outbound message types.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(3): Electronic prescribing | (b)(3)(ii)(C)(1) - Primary/Secondary Diagnosis |
Justification
WebChart EHR must be able to send Diagnosis codes in outbound e-prescribing messages, and receive inbound messages that include them.
Test Methodology
MIE will report the contents of each stored message in a client’s local database table of stored messages, and counts the inbound and outbound messages that include Diagnosis elements. MIE will run the report for each client under consideration and aggregate the results.
Results
Total NewRx Messages | NewRx Messages with Diagnosis Included |
433274 | 141266 |
Total rate of diagnosis use: 141266 / 433274 * 100 = 32.6%
Discussion
Since the Diagnosis elements are not a required component of a NewRx message, as anticipated, only a subset (32.6%) of the NewRx messages included a diagnosis. The rate of NewRx messages with a diagnosis included increased from 28.99% in 2022 to 32.6% in 2023 showing an increasing rate of using the diagnosis element. Most clients appear to heavily use the diagnosis element, with only one tested client rarely including a diagnosis and therefore reducing the overall usage rate. Additional client education will be provided in 2024 to further increase usage.
Measure 5: E-Prescribing Oral Liquid Units
Description
This measure will verify that prescriptions for medications with an oral liquid form will have a quantity unit of measurement of mL, not cc or English units as outlined in §170.315(b)(3).
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(3): Electronic prescribing | (b)(3)(ii)(E) - Metric Units |
Justification
WebChart EHR should prevent prescriptions of oral liquid medications from being sent electronically if they have an inappropriate quantity unit of measurement.
Test Methodology
MIE will create a system report that examines the contents of each stored NewRx message in a client’s local database table of stored messages, limiting to oral liquid medications, and provides a count of each distinct quantity unit of measure used. MIE will run the report for each client under consideration and aggregate the results. Units of Presentation
Results
Unit Code | Unit Description | Quantity |
C28254 | Milliliter (ml) | 14460 |
C48155 | Gram (g) | 1 |
C48477 | Bottle | 0 |
C48480 | Capsule | 1 |
C48521 | Packet | 4 |
C48542 | Tablet | 7 |
C64933 | Each | 15 |
C48504 | Kit | 2 |
Total rate of incorrect units: 30 / 14490 * 100 = 0.21%
Discussion
As expected, C28254 (milliliters) is the most commonly sent unit of measure for oral liquid medications. Non-C28254 units were only sent in 0.21% of oral liquid medication messages in 2023 which was a decrease from 0.24% sent in 2022.
Measure 6: E-Prescribing Decimal Format
Description
This measure will verify that numeric amounts in prescriptions include leading zeros before decimal points and do not allow trailing zeros after a decimal point.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(3): Electronic prescribing | (b)(3)(ii)(F) - Decimal Format |
Justification
WebChart EHR should prevent prescriptions from being sent electronically if they have directions or total quantity that are missing leading zeros or include trailing zeros. This is essential for preventing misunderstanding by pharmacists regarding the amount to dispense and patients regarding the amount of medication to take.
Test Methodology
MIE will create a system report that examines the contents of each stored NewRx message in a client’s local database table of stored messages, and provides a count of prescription messages that include inappropriate trailing zeros, and a count of those missing leading zeros. MIE will run the report for each client under consideration and aggregate the results.
Results
Total NewRx Messages | NewRx Messages with Improper Decimal Format |
437559 | 2545 |
Discussion
As expected, the number of NewRx messages sent with inappropriate trailing zeros, or missing leading zeros, occurs rarely in only 0.58% of messages; however, this is again an increase from the 0.43% seen across 2022 and 0.55% seen in Q1 of 2023. Both technical and training options will be investigated to reduce the incidence of improper decimal formats in 2024.
Measure 7: CDA Download
Description
This measure will verify that the system can accept a CDA document uploaded into the system, assign it to the appropriate chart in the system as appropriate, and display the document with a standard stylesheet with all sections being accepted and visible.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(2): Clinical information reconciliation and incorporation | (b)(2)(ii) - Correct patient. |
§170.315(b)(1): Transitions of Care | (b)(1)(ii) - All paragraphs |
(b)(1)(iii) - All paragraphs |
Justification
Webchart EHR should be able to accept a CDA document and place it into the correct chart based on information within the document. It should also be able to display the CDA documents with an appropriate stylesheet.
Test Methodology
MIE will report on the number of CDA formatted documents uploaded into tracked WebChart EHR systems and the number of upload attempts that failed as stored in client databases and error log files.
MIE will report on the number of requests to view a CDA document within the system, and the number of times it displayed correctly, and when there were errors in display.
Any errors reported by customers or the recipients of their quarterly attestations will be tracked and reported as a baseline. These test assumptions for customer reporting align with the “visual inspection” aspects of the test lab tests.
Results
Documents | Views |
93198 | 28543 |
Discussion
Significantly more documents were uploaded into WebChart EHR than were viewed; however, all 28543 document views that did occur were successful. No errors were reported by clients.
Measure 8: Application Access Documentation
Description
This measure will verify that WebChart EHR’s API documentation is publicly and perpetually available. Compliance will be recorded by an external uptime monitor and reported quarterly. Upon request, or in the event of downtime, data can additionally be reported in daily, weekly, or monthly increments.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(7): Application access – patient selection | (g)(7)(ii)(A)(1) - Functional Documentation |
(g)(7)(ii)(A)(2) - Implementation Requirements | |
(g)(7)(ii)(A)(3) - Terms of Use | |
(g)(7)(ii)(B) - Public Link | |
§170.315(g)(8): Application access – data category request | (g)(8)(ii)(A)(1) - Documentation |
(g)(8)(ii)(A)(2) - Implementation Requirements | |
(g)(8)(ii)(A)(3) - Terms of Use | |
(g)(8)(ii)(B) - Public URL | |
§170.315(g)(9): Application access—all data request | (g)(9)(ii)(A)(i) - Documentation |
(g)(9)(ii)(A)(ii) - Implementation Requirements | |
(g)(9)(ii)(B) - Public URL |
Justification
WebChart EHR should provide public access to all API documentation, implementation requirements, and terms of use as outlined in 170.315(g)(7), 170.315(g)(8), and 170.315(g)(9). This documentation should be available at all times throughout the year.
Test Methodology
An external uptime monitor will check the availability of all documentation available at https://docs.webchartnow.com/resources/system-specifications/application-programming-interface-api.html . Both up- and downtime will be logged to be reported quarterly. The cause of any downtime and the duration will also be logged In the event of any downtime, the amount of downtime can be reported at daily, weekly, or monthly intervals in addition to the quarterly reports, and the cause of each downtime occurrence will be reported.
Results
The MIE API documentation was available 99.975% of the time in 2023 representing an overall increase from an availability of 99.967% in 2022.
The MIE API documentation was available 99.991% of Q1. There was a 6 minute down period on March 8, 2023 and a 1 minute down period on March 9, 2023 due to a connection timeout.
The MIE API documentation was available 99.914% of Q2. There was a 1 hour 51 minute down period on June 13, 2023 due to a connection timeout.
The MIE API documentation was available 100% of Q3.
The MIE API documentation was available 99.995% of Q4. There was a 1 minute down period on November 30, 2023 and a 5 minute down period on December 15, 2023 due to a connection timeout.
Discussion
As expected, the documentation maintained an uptime of greater than 99.9% at 99.975% for the year. During any down time the API documentation would not have been available, but, no effect to end user requests for the information was reported. Data regarding the usage of the API can be viewed in Measure 20.
Measure 9: Clinical Information Reconciliation and Incorporation
Description
This measure will verify that the system can take a CCDA transition of care/referral summary formatted according to the standards adopted §170.205(a)(3) and §170.205(a)(4) and read the data for medications, allergies, and conditions from the document, reconcile those into the chart, and that the data is fully incorporated into the chart.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(2): Clinical information reconciliation and incorporation | (b)(2)(iii)(A), (B), (C), (D) |
(b)(2)(iv) - System Verification |
Justification
WebChart EHR should be able to reconcile CCDA data for medications, allergies, and conditions into a patient’s chart as outlined in § 170.315(b)(2).
Test Methodology
MIE will report on the number of CDA formatted documents reconciled via our reconciliation process.
Following each reconcile, if a temporary CDA for the chart is created as part of the process, it will be validated to ensure the reconciled data can be incorporated into a CDA created free of schematic errors (the CDA document will NOT be kept, only the result of the validation). Additionally, any client complaints that data is not being imported correctly from the tool will be tracked, investigated, and reported.
Results
CDA Documents reconciled:
Total Reconciled Documents | Schematically Valid | Schematically Invalid |
740 | 309 | 431 |
Discussion
All documents marked as schematically invalid were from a 3rd party interface sent into the system; however, all invalid documents still imported successfully and can be viewed in the system in human-readable format.
Measure 10: Transmission to Immunization Registry: Create Content
Description
This measure will verify that the system can generate a VXU conforming to the HL7 v2.5.1 standard, CDC guidance for communication to Immunization Registries and state/local guidance. The VXU messages shall contain information related to the demographics and vaccination administration record.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(f)(1): Transmission to immunization registries | (f)(1)(i) - Create Content |
Justification
WebChart EHR should be able to generate and send valid VXU messages.
Test Methodology
MIE will report from the database the number of successfully sent VXU messages acknowledged as received by the state immunization registry. MIE will also report from the database on the number of records rejected by the state registry due to error, whether the failure was due to registry internal errors, clinical data entry issues or a not well-formed message. Finally, MIE will report from the database the number of messages which declined to be generated due to data entry issues failing message pre-validation.
Results
Successful | Failures | Data Entry Validation Issue |
8258 | 7 | 7 |
Discussion
All 7 of the Failures were related to user data entry. For two of the failures, the user entered an administration location which was then changed to an outside location. The outside location was not a valid reporting location causing the error. The remaining error occurred when the date of administration was after the expiration date of the vaccination and was rejected by the registry.
For the 7 Data Entry Validation issues, 3 were duplicate records which were deleted, two did not have a valid CVX code selected, one did not have an administration date entered, and one vaccination record had a manufacturer not recognized by the CDC.
Measure 11: Transmission to Immunization Registries: Query Records
Description
This measure will verify that the system can generate a QBP conforming to the HL7 v2.5.1 standard, CDC guidance for communication to Immunization Registries and state/local guidance. Furthermore, the system shall be able to retrieve, consume and display to the end user the results of any such query.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(f)(1): Transmission to immunization registries | f)(1)(ii) - Query Records |
Justification
WebChart EHR should be able to request, consume and display an evaluated patient history and forecast.
Test Methodology
MIE will report the number of successful retrievals of evaluated history and forecasting operations from the database. MIE will report the number of failed retrievals, including those resulting from an internal error in the registry resulting in an inability to consume a response from the database. MIE will manually track, resolve and report issues resulting from WebChart EHR application errors as reported by end users.
Results
Successful: 26580
Failure: 501
Discussion
The failure rate is very low with clusters of failures around a few points in time. This is to be expected due to network, server or other technology related issues.
Measure 12: Direct Project: Send
Description
This measure will verify that the system can transmit a Direct project conforming S/MIME to a HISP. The measure will also verify the receipt of those transmissions by verifying the status of the resultant MDN messages.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(h)(1): Direct Project | (h)(1)(i) - Send |
(h)(1)(ii) - Message Disposition Notification: Processed | |
(h)(1)(ii) - Message Disposition Notification: Failed |
Justification
WebChart EHR should be able to generate valid S/MIME messages, transmit them via Direct Project specifications and consume the resulting MDN from the recipient.
Test Methodology
MIE will report from log files the number of messages transmitted. MIE will report from logs the number of messages which failed to be transmitted whether due to internal error, external failures or inability to verify trust of the recipient. MIE will report from logs the number of Processed MDN messages received. MIE will report from logs the number of Failed MDN messages received.
Results
Transmitted: 3
Failed: 20
Processed MDNs: 3
Failed MDNs: 0
Discussion
The messages which failed to send fall into a handful of categories. The majority of the failures were the 17 messages with untrusted recipients. 3 failed due to our own certificate being expired which upon notification of the expiration was updated.
Measure 13: Direct Project: Receive
Description
This measure will verify that the system conforms to Direct Project message receipt requirements for validation.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(h)(1): Direct Project | (h)(1)(i) - Receive |
Justification
WebChart EHR should be able to receive, validate and deliver Direct Project messages transmitted to its HISP.
Test Methodology
MIE will report from logs the number of messages transmitted to the HISP. MIE will report from logs the number of messages failing to conform to Direct Project specifications. MIE will report from logs the number of messages which are successfully delivered to recipients.
Results
Received: 1545
Failed specifications: 3
Delivered messages: 1545
Discussion
All inbound messages were successfully delivered. There were 3 messages received which were delivered successfully but the system was unable to generate an MDN response due to a missing start boundary in the original message.
Measure 14: Patient Portal View
Description
This measure will verify that a patient can view various document types within the patient portal.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(e)(1): View, download, and transmit to 3rd party | (e)(1)(i)(A)(1),(2),(3),(4),(5) |
(e)(1)(i)(D)(1), (2) | |
(e)(1)(ii)(A) |
Justification
WebChart EHR should be able to provide a mechanism for a patient to read documents sent to them within a patient portal as required by § 170.315(e)(1).
Test Methodology
MIE will report a number of measurements surrounding documents, including:
- Number of documents made available to patients in the patient portal
- Number of documents read by patients in the patient portal
- Number of failures in the ability to read messages in the patient portal
Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files as well as any client reported issues tracked during the testing period.
Results
There were 15 views of 10 CDA documents in 2023 in tracked client systems.
Discussion
Both portal usage and, especially, CDA document viewing by patients are very low. It was anticipated that through further education, testing would be more robust using real patient data. To address this low volume in 2024, MIE will continue to educate for portal usage while also implementing more robust data collection on test data in production environments.
Measure 15: Patient Portal Download
Description
This measure will verify that a patient can download various document types within the patient portal.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(e)(1): View, download, and transmit to 3rd party | (e)(1)(i)(B)(1), (2), (3) |
(e)(1)(i)(D)(1), (2) | |
(e)(1)(ii)(A) |
Justification
WebChart EHR should be able to provide a mechanism for a patient to download documents sent to them within a patient portal.
Test Methodology
MIE will report a number of measurements surrounding documents, including:
- Number of documents made available to patients in the patient portal
- Number of documents successfully downloaded from the patient portal
- Number of documents unsuccessful in being downloaded from the patient portal.
Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files and third party reports as well as any client reported issues tracked during the testing period.
Results
There were 8 streams of 3 CDA documents in 2023 in tracked client systems.
Discussion
Both portal usage and, especially, CDA document downloading by patients are very low. It was anticipated that through further education, testing would be more robust using real patient data. To address this low volume in 2024, MIE will continue to educate for portal usage while also implementing more robust data collection on test data in production environments.
Measure 16: Patient Portal CCDA Transmit
Description
This measure will verify that a patient can transmit various document types within the patient portal to other entities.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(e)(1): View, download, and transmit to 3rd party | (e)(1)(i)(C)(1), (2) |
(e)(1)(i)(D)(1), (2) | |
(e)(1)(ii)(A) |
Justification
WebChart EHR should be able to provide a mechanism for a patient to transmit documents sent to them within a patient portal to other entities.
Test Methodology
MIE will report a number of measurements surrounding documents, including:
- Number of documents made available to patients in the patient portal
- Number of documents successfully transmitted from the patient portal
- Number of documents unsuccessful in being transmitted from the patient portal.
Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files and third party reports as well as any client reported issues tracked during the testing period.
Results
3 exports of 2 CDA documents were reported in 2023 in tracked client systems.
Discussion
Both portal usage and, especially, CDA document transmission by patients are very low. It was anticipated that through further education, testing would be more robust using real patient data. To address this low volume in 2024, MIE will continue to educate for portal usage while also implementing more robust data collection on test data in production environments.
Measure 17: Send Using Edge Protocol for SMTP / XDM
Description
This measure will verify that the system is able to utilize a SMTP edge protocol for sending and receiving Direct Project messages. As part of receiving messages, XDM shall be handled when applicable.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(1): Transitions of Care | (b)(1)(i)(A)(Alternative) - Send Using Edge Protocol for SMTP/IXE XDR |
(b)(1)(i)(B)(Alternative) - Receive Using Edge Protocol for SMTP/IXE XDR | |
(b)(1)(i)(C)(Conditional) - XDM Processing |
Justification
WebChart EHR should be able to receive and send Direct Project messages to a HISP utilizing a SMTP edge.
Test Methodology
MIE will report from logs the number of messages transmitted to the HISP by SMTP. MIE will report from logs the number of messages received from the HISP by SMTP. MIE will report from logs the number of XDM packages processed. In the case where insufficient real-world data is available, data resulting from regular testing with DirectTrust shall be included in the reporting.
Results
Transmitted to HISP via SMTP: 1545
Transmitted by HISP: 3
XDM packages processed: 505
Discussion
A growing number of incoming Direct Messages contained XDM packages. These were processed successfully by the system. Outbound Direct Message usage is still low. To address this low volume in 2024, MIE will continue to educate for portal usage while also implementing more robust data collection on test data in production environments.
Measure 18: Data Export
Description
This measure will verify that a user can use WebChart EHR’s Data Export Tool to pull down groups of patient data from a WebChart EHR system.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(6): Data Export | (b)(6)(i) |
(b)(6)(ii)(A)-(F) | |
(b)(6)(iii)(A)-(B) | |
(b)(6)(iv) |
Justification
WebChart EHR should be able to provide a mechanism for a user to download patient chart information via CDA from a large set of patients within the system as outlined in §170.315(b)(6). This tool is publicly available ( https://github.com/mieweb/wcexport) .
Test Methodology
MIE will report from the event log database tables a series of occurrences that indicates use of the WebChart EHR Data Export Tool:
- Event logs of the report to find all patients for Document Export being called.
- Event logs of CDA documents being generated within a certain short time period following the report.
MIE will track customer reports of data expected to be in mass data export downloads that did not download as failures.
Results
A mass data export of 12,563 CDA documents occurred in a client system in early November. The documents generated were known to have been used in another system for import later on in the month. All 12,563 documents were successfully imported.
Discussion
The mass export of CDA documents is a rarely used feature; however, as expected, all documents were successfully generated and successfully imported into the new system.
Measure 19: CDA Validation
Description
This measure will verify that CDAs both created by and received by a WebChart EHR system pass basic CDA validation.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(1): Transitions of Care | (b)(1)(ii)(A) |
§170.315(b)(6): Data Export | (b)(6)(ii), (A)-(F) |
Justification
WebChart EHR should be able to validate that CDAs that are stored within WebChart EHR either do or do not conform to basic CDA schema requirements.
Test Methodology
All CDAs stored within a WebChart EHR will be run through schema validation regardless of the document’s origin. Documents may originate within the WebChart EHR system or be imported from a third party application of manual upload. The schema validator will be installed within the MIE production environment to ensure the security of all PHI contained in the documents. Only results of the validation will be made available, document content will not be revealed to developers during testing.
The number of valid vs. invalid CDAs and their sources will be reported.
Results
All Documents:
Valid CDAs: 1079
Invalid CDAs: 2319
Discussion
The bulk of these results are from 3rd party uploaded documents.
For the WebChart EHR generated documents, most errors occurred because of vitals data coming from external systems was stored incorrectly and put into the CCDA document in that incorrect form (ie, a value of “5 ft 4 in”, when PQ values can only be numeric). To prevent such “pass-along” errors in the future, new policies will be investigated and implemented in 2024 to ensure better generated CDA validity.
Measure 20: Patient Data requests VIA API
Description
This measure will verify that the API as outlined in WebChart EHR’s documentation is functional. A valid request for patient information must provide that information.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(7): Application access – patient selection | (g)(7)(i) - Query processing and response |
§170.315(g)(8): Application access – data category request | (g)(8)(i)(A) - Return CCDS data |
(g)(8)(i)(B) - Request response | |
§170.315(g)(9): Application access—all data request | (g)(9)(i)(A)(1) - Demonstrate API |
(g)(9)(i)(A)(3) - Data Classes | |
(g)(9)(i)(B) - Data Return |
Justification
WebChart EHR should provide patient information to requesters with the proper access to the information. In production environments of WebChart EHR, the use of the documented API is rare; therefore, MIE will conduct dual level testing of the API first, using automated testing of a test system in a production environment and second, manually tracking any client reported issues with the API functionality against the automatically tracked API requests are made.
Test Methodology
To address the overall automated testing, the following test requests will be made daily against a test system in a production environment.
- Issue a request in the browser to search for a patient (patient selection)
- Issue a request in the browser to request demographics of a patient (data category request)
- Issue a request using the export tool described in the documentation.
All API requests made in production systems are recorded in log files. The number of requests logged will be reported against the number of issues with API functionality that are reported.
Results
Production Exports | 5 |
Total Charts Exported | 481258 |
Total Export Errors | 0 |
Discussion
Five total production API exports occurred in 2023. Three of these exports produced CSV files and two produced PDF files for patient charts. All exports had an initial failure rate of <1%. These initial export errors were rerun error-free and 100% of data was delivered as expected.
Measure 21: Web Content Accessibility
Description
This measure will verify that all certified content in the patient portal will maintain accessibility conformance as outlined in the Web Content Accessibility Guidelines (WCAG) 2.0.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(e)(1): View, download, and transmit to 3rd party | (e)(1)(i) - Web Content Accessibility |
Justification
The certified content of the patient portal should be accessible to all users regardless of abilities or impairments as outlined in the Web Content Accessibility Guidelines (WCAG) 2.0.
Test Methodology
MIE will conduct monthly third-party production accessibility scanning as well as automated nightly internal accessibility scanning of a test system in a production environment.
Results
The internal accessibility scanning of a pre-production test system identified 0 urgent and 0 secondary non-conformance issues in 99.13% of nightly and ad-hoc scans throughout the year. In the remaining 0.87% of scans only secondary issues were uncovered, all of which were eliminated prior to code changes reaching production systems. Production accessibility scanning identified 0 urgent and 0 secondary non-conformance issues for the entire year.
Discussion
As expected no urgent non-conformance issues were identified in either live production or pre-production test systems. In the rare occurrence that a secondary non-conformance issue was identified in testing, it was addressed and eliminated prior to reaching live production systems.
Measure 22: FHIR API Documentation
Description
This measure will verify that WebChart EHR’s FHIR API documentation is publicly and perpetually available. Compliance will be recorded by an external uptime monitor and reported quarterly. Upon request, or in the event of downtime, data can additionally be reported in daily, weekly, or monthly increments.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(10): Standardized API for patient and population services | (g)(10)(vii) - Documentation |
Justification
WebChart EHR should provide public access to all FHIR API documentation, software components, software configurations, registration instructions, and terms of use as outlined in 170.315(g)(10). This documentation should be available at all times throughout the year.
Test Methodology
An external uptime monitor will check the availability of all documentation available at https://docs.webchartnow.com/resources/system-specifications/fhir-application-programming-interface-api/ and the linked subpages. Both up- and downtime will be logged to be reported quarterly. The cause of any downtime and the duration will also be logged In the event of any downtime, the amount of downtime can be reported at daily, weekly, or monthly intervals in addition to the quarterly reports, and the cause of each downtime occurrence will be reported.
Results
The FHIR API documentation was available 99.975% of the time in 2023 representing an overall increase from an availability of 99.967% in 2022.
The FHIR API documentation was available 99.991% of Q1. There was a 6 minute down period on March 8, 2023 and a 1 minute down period on March 9, 2023 due to a connection timeout.
The FHIR API documentation was available 99.914% of Q2. There was a 1 hour 51 minute down period on June 13, 2023 due to a connection timeout.
The FHIR API documentation was available 100% of Q3.
The FHIR API documentation was available 99.995% of Q4. There was a 1 minute down period on November 30, 2023 and a 5 minute down period on December 15, 2023 due to a connection timeout.
Discussion
As expected, the documentation maintained an uptime of greater than 99.9% at 99.975% for the year. During any down time the FHIR API documentation would not have been available, but no effect on end user requests for the information was reported.
Measure 23: CCDA Content
Description
This measure will verify that CCDAs generated in WebChart EHR systems have all USCDI data and other required data.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(e)(1) View, download, and transmit to 3rd party | (e)(1)(i)(A)(1) - (e)(1)(i)(A)(7) |
Justification
WebChart EHR should generate CCDAs that can generate the sections required by USCDI.
Test Methodology
We will have tests that will choose a certain number of random patient CCDAs in specific live systems and test for the given sections to exist in the documents.
Results
On a quarterly basis, USCDI data elements have been entered on 2 test patients in live WebChart EHR systems. Each quarter, 1 CCDA document was generated for each test patient. All 8 CCDA documents contained all USCDI data elements.
Additionally, the 28543 CCDA documents viewed in participating WebChart EHR systems and the 309 schematically valid reconciled CCDA documents were compared to the patients’ charts. In all cases, all USCDI data available in the chart was displayed in the documents.
Discussion
All testing completed with test patients in live systems was successful, demonstrating that all USCDI elements can be included in CCDAs. All live patient data tested was also successful; however, not all patient charts contained all USCDI data elements. More robust testing of all USCDI elements is planned for 2024.
Measure 24: Record and Change Care Plan
Description
This measure will track that users can create and change care plan data.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(9): Care plan | Record, Change and Access |
Justification
WebChart EHR per certification requirements must be able to provide a way to enter and update Care Plan data.
Test Methodology
We will report on the following data elements being created or edited in patient charts:
- Goals
- Health concerns
- Health status evaluations and outcomes
- Interventions
Results
On a quarterly basis, CDA Care Plan information was entered on test patients in properly configured live WebChart EHR systems. CCDA documents were then generated for those patients. In all cases the Care Plan information was present in the CCDA.
The following is the number of records of each element in the live systems tested:
Element | Number of Charts with Element Entered per Quarter |
Care Plan Goals | 4 |
Health Concerns | 3 |
Health Status | 2 |
Interventions | 2 |
Discussion
Currently, no live clients are using the CCDA related Care Plan fields in their workflows; however, 100% of completed tests were successful.
Measure 25: Create Care Plan CCDA Documents
Description
This measure will track that users can create Care Plan CCDA Documents.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(9): Care plan | Requirement from matrix |
Justification
WebChart EHR per certification requirements must be able to generate Care Plan CCDA Documents.
Test Methodology
We will report on the number of encounters with Care Plan information, and the number of Care Plan CCDAs generated.
Results
On a quarterly basis, CDA Care Plan information was entered on test patients in properly configured live WebChart EHR systems. CCDA documents were then generated for those patients.
Element | Number of Charts with Element Entered per Quarter | Number of CCDAs with Element Present per Quarter | Total Successful Tests |
Care Plan Goals | 4 | 4 | 16 |
Health Concerns | 3 | 3 | 12 |
Health Status | 2 | 2 | 8 |
Interventions | 2 | 2 | 8 |
Discussion
In 2023, no live clients were generating Care Plan CCDAs as part of their workflows; however, 100% of completed tests were successful.
Measure 26: Receive Care Plan CCDA Documents
Description
This measure will track that the system can receive Care Plan CCDA Documents.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(9): Care plan | Requirement from matrix |
Justification
WebChart EHR per certification requirements must be able to receive Care Plan CCDA Documents.
Test Methodology
We will report on:
* the number of Care Plan CCDAs received from outside sources.
* Pass or fail count on the Care Plan CCDAs received.
Results
On a quarterly basis, CCDA documents with Care Plan information were imported to test patients in live WebChart EHR systems. CCDA documents with Care Plan information were imported for 4 test patients separate from the test patients used in Measures 24 and 25.
4 CCDA documents were uploaded each quarter for a total of 16 documents. All 16 were successful.
Discussion
As expected, all manual testing was successful. Currently, no clients are set up to receive Care Plan CCDA documents as part of their workflow. Whether any live clients will receive CCDA Care Plan documents as a live part of their workflow is not certain, so expanded manual live testing will be implemented in 2024.
Measure 27: Create CCDA Documents with Security Tags
Description
This measure will track that the system can create CCDA Documents with valid security tags.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(7): Security tags - summary of care - send | (b)(7) |
Justification
WebChart EHR per certification requirements must be able to generate CCDA Documents with valid security tags.
Test Methodology
We will have automated tests that run at minimum weekly to test that the software is still able to generate CCDAs with Security Tags.
From discussions with others around the industry who interact with large usage of CDA creation and transmission, there is little to no usage of DS4P within documents created by systems currently. If we determine that we are seeing usage of the security tagging within Production systems, we will report:
* the number of CCDAs received during the RWT period.
* The number of CCDAs with security tags received during the RWT period.
Results
On a quarterly basis, CDA documents were generated on test patients with security set on the encounter in live WebChart EHR systems. Across the year, 23 documents with security tags were generated. All 23 documents were reviewed and contained the appropriate security tags based on the encounter settings. Additionally, all 23 documents were confirmed as valid CCDAs. These documents were then imported into a test system, and all were confirmed to have successfully imported the appropriate security.
Discussion
Since there are no indications that the security tags will be broadly used within live workflows, more robust manual testing will be implemented in 2024 along with client education that this feature is available.
Measure 28: Receive and Display CCDA Documents with Security Tags
Description
This measure will track that the system can receive CCDA Documents with security tags and properly display them to end users.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(b)(8): Security tags - summary of care - receive | (b)(8)(i) and (ii) |
Justification
WebChart EHR per certification requirements must be able to receive CCDA Documents with security tags and properly display them to end users.
Test Methodology
We will have automated tests that run at minimum weekly to test that the software is still able to generate CCDAs with Security Tags.
From discussions with others around the industry who interact with large usage of CDA creation and transmission, there is little to no usage of DS4P within documents created by systems currently. If we determine that we are seeing usage of the security tagging within Production systems, we will report:
* the number of CCDAs received during the RWT period.
* The number of CCDAs with security tags received during the RWT period.
Results
On a quarterly basis, CDA documents were generated on test patients with security set on the encounter in live WebChart EHR systems. Across the year, 23 documents with security tags were generated. All 23 documents were reviewed and contained the appropriate security tags based on the encounter settings. Additionally, all 23 documents were confirmed as valid CCDAs. These documents were then imported into a test system, and all were confirmed to have successfully imported the appropriate security.
Discussion
Since there are no indications that the security tags will be broadly used within live workflows, more robust manual testing will be implemented in 2024 along with client education that this feature is available.
Measure 29: FHIR Sandbox Testing
Description
This measure will use the Inferno Test suite to validate all types of secure connections and search operations supported by the FHIR API within a publicly available production sandbox system.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(10): Standardized API for patient and population services | (g)(10)(i) - Data response: USCDI v1 + US Core STU v3.1.1 |
(g)(10)(ii) - Supported search operations | |
(g)(10)(iii) - Application registration | |
(g)(10)(iv) - Secure connection | |
(g)(10)(v)(A) - Authentication and authorization for patient and user scopes: SMART 1.0.0 | |
(g)(10)(v)(B) - Authentication and authorization for system scopes | |
(g)(10)(vi) - Patient authorization revocation |
Justification
WebChart EHR’s FHIR API is still newly available to clients and has no adoption as of writing this plan. Therefore to cover testing prior to live clients actively using the API, a publicly available production sandbox will be tested using Inferno. FHIR adoption is expected to be slow, but increasing, throughout 2023 leading to improved app support in WebChart EHR as well as increased real world data being available, at which time, Measures 30 and 31 will provide a more complete view of the production FHIR capabilities.
Test Methodology
MIE will run weekly automated testing on the public FHIR R4 sandbox system using Inferno, and using log files stored in a QA database, MIE will report the success rate of the full (g)(10) test suite. Any errors will be tracked, reported, and addressed.
Results
Beginning in Q3, weekly testing of the FHIR Sandbox using Inferno was conducted since no live clients are currently using FHIR. 15 of these tests were fully successful. Weekly tests that were not successful were due to internal issues with test server availability. The FHIR Sandbox environment was always available, but the test system accessing it had unexpected unavailability impacting our ability to test the sandbox.
Discussion
When the test server was available for connection to the FHIR Sandbox, FHIR Inferno testing was successful. MIE plans to both continue with weekly testing beginning from 01/01/2024 and work with clients to robustly test real world scenarios throughout all of 2024.
Measure 30: FHIR Patient Scope
Description
This measure will review WebChart EHR’s ability to connect to an app within a patient scope and provide the user with the requested data.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(10): Standardized API for patient and population services | (g)(10)(i) - Data response: USCDI v1 + US Core STU v3.1.1 |
(g)(10)(ii) - Supported search operations | |
(g)(10)(iii) - Application registration | |
(g)(10)(iv) - Secure connection | |
(g)(10)(v)(A) - Authentication and authorization for patient and user scopes: SMART 1.0.0 | |
(g)(10)(vi) - Patient authorization revocation |
Justification
WebChart EHR’s FHIR API is still newly available to clients, and has no adoption as of writing this plan. FHIR adoption is expected to be slow, but increasing, throughout 2023 leading to improved app support in WebChart EHR as well as increased real world data being available. Until that time when clients are actively using the FHIR API, MIE will conduct testing using a publicly available production sandbox system and a patient app recommended to our clients. As clients continue adoption of the FHIR API, real patient use of the patient app will be reported.
Test Methodology
MIE will report from de-identified log files an analysis of authentication and data searches using a patient app. Specific rates can be reported from the sandbox system as the automated testing setup will indicate what actions should yield successful authentication or data return. An overall analysis will be reported for the real world patient data since we cannot estimate failures due to patients correctly being denied access.
Results
No client systems have generated FHIR patient connections yet.
Successful Sandbox connections have been made via:
- Our Inferno testing tool : 658 successful Patient scope FHIR connections.
- The CommonHealth app: 14 successful Patient scope FHIR connections.
Discussion
MIE is in active discussions with the CommonHealth app to connect both the FHIR Sandbox and a live client for portal patients. We also have plans on getting Apple Health Kit connectivity in 2024.
Measure 31: FHIR EHR Provider Scope
Description
This measure will review WebChart EHR’s ability to connect to an app within an EHR provider scope and provide the user with the requested data.
Associated Certification Criteria
Certification Criteria | Requirement(s) |
§170.315(g)(10): Standardized API for patient and population services | (g)(10)(i) - Data response: USCDI v1 + US Core STU v3.1.1 |
(g)(10)(ii) - Supported search operations | |
(g)(10)(iii) - Application registration | |
(g)(10)(iv) - Secure connection | |
(g)(10)(v)(B) - Authentication and authorization for system scopes |
Justification
WebChart EHR’s FHIR API is still newly available to clients, and has no adoption as of writing this plan. FHIR adoption is expected to be slow, but increasing, throughout 2023 leading to improved app support in WebChart EHR as well as increased real world data being available. Until that time when clients are actively using the FHIR API, MIE will conduct testing using a publicly available production sandbox system and a provider app recommended to our clients. As clients continue adoption of the FHIR API, real provider use of the provider app will be reported.
Test Methodology
MIE will report from de-identified log files an analysis of authentication and data searches using a patient app. Specific rates can be reported from the sandbox system as the automated testing setup will indicate what actions should yield successful authentication or data return. An overall analysis will be reported for the real world provider data since we cannot estimate failures due to providers correctly being denied access.
Results
111 successful Sandbox connections to our Inferno testing tool were made for EHR provider access.
Discussion
The Live RW sandbox systems have shown our ability to do EHR provider connections. We will be looking for opportunities to connect client systems with EHR provider FHIR endpoints in 2024.
Schedule of Key Milestones
Key Milestone | Care Setting | Date/Timeframe | Status |
Release of documentation for the Real World Testing to be provided to ACB and providers | All settings | November 1, 2022 | Complete |
Begin collection of information as laid out by the plan | All settings | January 1, 2023 | Complete |
Follow-up with providers and authorized representatives to understand any issues arising with the data collection. | All settings | Quarterly, 2023 | Complete |
Data collection and review. | All settings | Quarterly, 2023 | Complete |
New certification of b.10 | All settings | Q3, 2023 | Complete, Q4 |
Additional CQM or criteria certification as determined by the developer | All settings | Q3, 2023 | f.5 certification complete, Q4 |
End of Real World Testing period/final collection of all data for analysis | All settings | December 31, 2023 | Complete |
Data analysis and report creation | All settings | January, 2024 | Complete |
Submission of Real World Testing Results to ACB | All settings | Jan 29, 2024, resubmitted on Feb 29, 2024 |
Attestation
This Real World Testing plan is complete with all required elements, including measures that address all certification criteria and care settings. All information in this plan is up to date and fully addresses the health IT developer’s Real World Testing requirements.
Authorized Representative Name | Doug Horner |
Authorized Representative Email | horner@mieweb.com |
Authorized Representative Phone | 260-459-6270 |
Authorized Representative Signature | Doug Horner |
Date | 02/29/2024 |
Enterprise Health Documentation
Last Updated:
Last Build:
Thu, 26 Sep 2024 13:57:52 UTC
WikiGDrive Version: dd69069d725fca5f553df7ded62e130a49d49ca6